WMV650F Veterinary Patient Monitor
Veterinary vital signs monitor WMV650F model is intended to be used in special procedure labs and other areas of a veterinary hospital or clinic where veterinary monitoring systems are needed. The monitor package includes 3-lead or 5-lead electrocardiography (ECG), noninvasive blood pressure (NIBP), temperature (TEMP) and pulse oximetry (SpO2).The device permits patient monitoring with adjustable alarm limits as well as visible and audible alarm signals. The monitor provides fast, reliable measurements for patientsranging from cats to horses when using the appropriate accessories.
تفاصيل المنتج
7" high resolution color LCD display with adjustable brightness.
Lightweight and portable, easy for veterinarians to carry out.
Built-in rechargeable lithium battery for long term continuous operation.
3 leads and 5 leads ECG cable are selectable.
Variety of NIBP Cuffs for different size animals.
Expanded heart rate values and Veterinary specific SpO2 sensors to accommodate a variety of species.
Widely used in pet hospitals and animal clinics etc.
Two-year warranty
مواصفات
Enclosure
RESP
Weight | 2.05kg (4.52 lb), including 1 battery |
Dimensions | 324mm Wx 129mm H x 183 mmD(12.76in. W x 5.08in. H x 7.20in. D) |
Display | |
Screen size | 177.8 mm (7in.), measured diagonally |
Screen type | TFT LCD, white LED backlight,viewing cone of 60°and optimal viewing distance of 1.5 meter |
Resolution | 800x480pixels |
Alarms | |
Categories | Patient status and system status |
Priorities | Low, medium, and high |
Notification | Audible and visual |
Setting | Full storage, low battery and sensor off |
Alarm volume level | 45 to 85decibels |
Alarm system delay | <10seconds |
Aturation range | 0-130rpm |
Accuracy | ±1 pm |
Resolution | Irpm |
TEMP | |
Aturation range | 0-50°C |
Accuracy | ±0.2°C |
Resolution | 0.1°C |
SpO2
Aturation range | 1% to 100% |
Accuracy | 70-100% 仕2%), <70% undefined |
Resolution | 1% |
Display sweep speed | 10.00 mm/sec |
Pulse Rate | |
Aturation range | 25bpm to350bpm |
Accuracy | ±2bpm/±2% take maximum |
Resolution | Ibpm |
ECG | |
Aturation range | 25bpm to350bpm |
Accuracy | ±2bpm/±2% take maximum |
Resolution | Ibpm |
Leads | 1,11,III,V.aVR.aVL or aVL |
Display gain | Xl/4, Xl/2, XI, X2, X4 |
Display sweep speed | 6.25, 12.5, 25, 50mm/sec |
ETCO2 (Optional) | |
Mode | Sidestream |
Aturation Range | 0-150mmHg |
Accuracy | 0-40mmHg ±2mmHg41-150mmHg ±10% of reading |
Resolution | O.lmmHg |
Flow rate | 50ml/min ±10ml/min |
Electrical | |
Battery Four new lithium batteries with 4,400mAh will typically provide | |
4.5 hours of monitoring with no external communication, no | |
audible alarm sound, and at an ambient temperature of 2 5°C | |
Type Lithium Batteries, 4,400mAh, DC 11.IV | |
Voltage AC 100-240V, 50-60Hz, 80VA |
Environmental
Transport and Storage | Operating Conditions | |
Temperature | -40°Cto 75°C (-40°Fto 167°F) | 0°Cto 50°C (32°Fto 122°F) |
Altitude | -500 to 5,000m (-1,640 to 16,404ft.) | |
Relative humidity | 15% to 95% noncondensing |
Trend
NIBP
Tabular | |
Memory | Saves a total of 120 hours of data events; saves date and time, alarm conditions, measurements |
Tabular format | One table for all parameters |
Method | Oscillometric |
Aturation Range | 0-300mmHg |
Accuracy | Based on ANSI/AAMI SP10:1992 and 2002 Standards |
Measurement Time | 3O-5Os typical, 180s maximum |
AUTO Interval Times | 2, 3, 5, 10, 30 min, or 1, 2h |
Configuration
Standard | SpO2+ECG+NIBP+RESP+TEMP |
Optional | SpO2, SpO2+NIBP, SpO2+NIBP+ECG, SpO2+NIBP+TEMP SpO2+ECG+NIBP+RESP+TEMP+ETCO2, etc.Lithium Battery, Trolley, Brace, IPMS8600 Central monitoring system |